Eight common reliability models, computed right on this page. Everything runs locally in your browser — nothing is uploaded.
Results are for engineering reference. Confirm formal test plans against the standards, customer specs, and OEM requirements.
High-temperature acceleration: converts the target operating life into an equivalent test duration at T_opmax using the field temperature profile. Segments at or below T_opmax are converted via AF; segments above T_opmax keep real hours. k = 8.617e-5 eV/K.
| Field temp (°C) | Proportion (%) | |
|---|---|---|
Thermal-cycling acceleration: ACM = (ΔT_test / ΔT_field)^c and N_test = N_field / ACM. Also computes single-cycle duration and climate-chamber allocation X_CC.
Temperature-humidity acceleration (parking / storage): AF = (RH_test / RH_field)^n · exp[(E_A/k)(1/T_field − 1/T_test)] with humidity exponent 3 and E_A default 0.6 eV.
Vibration acceleration equivalence: W1 / W2 = (T2 / T1)^(1/m). Solve the equivalent duration T2 from W1, W2, T1 — or back-solve the equivalent level W2 from a target duration. PSD scales with the level squared.
Two-/three-parameter Weibull: point calculations (pdf, CDF, reliability, hazard, Bx life) and data fitting (MLE, censored MLE, RRX / RRY).
Classifies the failure phase from β (β<0.95 early failures DFR, β>1.05 wear-out IFR, otherwise useful life CFR), reports MTTF and B10/B50, and optimizes the preventive-maintenance replacement interval.
Reliability R = P(strength > stress). Normal-normal has the closed form R = Φ(z); other combinations (including Weibull) are integrated numerically. A classical safety factor is also reported.
Three demonstration plans: binomial success-run (R, C, allowed failures ↔ sample size); chi-square time-truncated (exponential MTTF ↔ total test time); Weibull parametric (zero failures, sample size ↔ test duration).
Select hardware changes and merge the recommended test list from the ZVEI HW-DQM matrix — export CSV / PDF online.
HW-DQM requalification →